onlinechem.pl marine
Technical guide

AUS 40 vs AdBlue (AUS 32): what actually differs

Two urea solutions, two standards, two tank designs. Using the wrong one changes dosing and can leave deposits in the system.

Updated: 18 November 2026

AUS 40 and AdBlue are not the same product. AdBlue is AUS 32 — a 32.5% aqueous urea solution specified by ISO 22241 for road vehicles. AUS 40 is a 40% solution specified by ISO 18611-1 for marine SCR. Different urea content, different standard, different tank. They are not interchangeable without recalibrating the dosing.

The difference in one table

AUS 40 (marine) AUS 32 (AdBlue)
Urea content 40% — commercial specifications report 39.5–40.5% m/m 32.5%
Standard ISO 18611-1 (quality), -2 (test methods), -3 (handling, transport, storage) ISO 22241
Designed for marine SCR, IMO Tier III road vehicles
Tank heated and insulated unheated is normal
Crystallisation higher than AUS 32 — see the note below commonly cited at about −11 °C
Typical packaging here IBC and road tanker canisters, IBC, pumps at filling stations

On the crystallisation point of AUS 40: you will find numbers repeated across supplier pages. We do not publish one we have not verified against a batch certificate. What is certain is the direction — more urea in the same volume means a higher crystallisation temperature than AUS 32, which is exactly why marine reagent tanks are heated and insulated. Ask us for the figure from the certificate for the batch you are buying.

Why marine settled on 40%

WinGD states that the standard aqueous urea solution for marine applications is 40%. The reason is tank volume: a 40% solution carries roughly a quarter more urea per litre than a 32.5% one, so the same reagent tank covers a longer period under Tier III operation. On a ship, where tank space is allocated once at the design stage and never gets cheaper, that matters.

The price of that choice is thermal. A more concentrated urea solution crystallises at a higher temperature, so the reagent tank, the lines and the dosing unit have to be heated and insulated. A truck cannot reasonably carry that, which is why road transport stayed at 32.5%.

What goes wrong when the wrong solution goes into the tank

  • Dosing drifts. An SCR metered for 40% urea that receives 32.5% injects about a fifth less urea per unit volume. NOx conversion falls, and on a Tier III engine that is a compliance problem, not just an efficiency one.
  • Deposits. Urea solutions that fall outside specification — on biuret, aldehydes or insolubles — leave residues in the injector and on the catalyst.
  • Catalyst life. Metals in an off-specification reagent poison the catalyst. That is the expensive failure mode, and it is cumulative rather than sudden.

This is not a theoretical concern. A 2023 TNO review reported that NOx emissions from Tier III ships are higher than the legislation intended and that owners report a substantial number of technical problems with SCR systems. Reagent quality is one of several causes — but it is the one you can eliminate with a piece of paper, before the product reaches the tank.

How much AUS 40 does an SCR actually use?

Published figures for Tier II to Tier III reduction sit in a band rather than at a point. ABS and WinGD both give roughly 18 g/kWh at full load; Wabtec uses 13.5 g/kWh as a stoichiometric baseline. Our estimator works on that 13.5–18 g/kWh range and converts the result into IBCs, with the assumptions shown rather than hidden.

A worked example: a 5 MW engine at 60% load running 24 hours under Tier III consumes roughly 1.6–2.2 tonnes of AUS 40 per day. Whatever the estimate says, your engine maker's project guide is the binding figure.

What to ask before you accept a delivery

  1. Which standard does the certificate reference — ISO 18611-1 or ISO 22241?
  2. Is the CoA for this batch, or a generic specification sheet?
  3. Does it report urea content, biuret, aldehydes, insolubles, alkalinity and metals?
  4. What is the density at 20 °C, so you can reconcile litres against kilograms on the delivery note?
  5. What is the crystallisation temperature for that batch, given how you store it?

A supplier who cannot answer all five from the paperwork is selling you a liquid, not a reagent.

Questions we get asked

Is AUS 40 the same as AdBlue?

No. AdBlue is AUS 32, a 32.5% aqueous urea solution specified by ISO 22241 for road vehicles. AUS 40 is a 40% solution specified by ISO 18611-1 for marine SCR systems. The urea content, the standard and the storage requirements all differ.

Can I run AdBlue in a marine SCR designed for AUS 40?

Not without consequences. A system metered for 40% urea that receives a 32.5% solution delivers roughly a fifth less urea per injected volume, so NOx conversion drops unless the dosing is recalibrated. Your engine and SCR documentation is the binding source — ask the manufacturer before substituting.

Why does marine use 40% and road transport 32.5%?

A 40% solution carries more urea in the same tank volume, which matters when tank space is scarce and voyages are long. The trade-off is a higher crystallisation temperature, so marine urea tanks are heated and insulated, which a road vehicle cannot easily provide.

Which standard should the certificate of analysis reference?

For AUS 40 it is ISO 18611-1, the quality requirements part of the series. ISO 18611-2 covers test methods and ISO 18611-3 covers handling, transport and storage. A CoA that references ISO 22241 is for AdBlue, not for marine AUS 40.

Sources

  • ISO 18611-1:2014, ISO 18611-2, ISO 18611-3 — quality requirements, test methods, and handling, transport and storage for AUS 40. ISO 18611-1 reviewed and confirmed in 2020.
  • ISO 22241 — the corresponding standard for AUS 32 (AdBlue).
  • WinGD, SCR FAQ — marine standard is a 40% aqueous urea solution; average reagent consumption around 18 g/kWh.
  • ABS, Advisory on NOx Tier III Compliance — about 18 g/kWh for Tier II to Tier III reduction at 100% load.
  • Wabtec — 13.5 g/kWh used as a stoichiometric basis for a 40% urea solution.
  • TNO (2023) — NOx emissions of Tier III ships higher than intended; owners report substantial technical issues with SCR systems.
  • Commercial AUS 40 specifications — urea 39.5–40.5% m/m, biuret max 0.5% m/m, aldehydes max 20 mg/kg, density 1105–1177 kg/m³ at 20 °C.

Need the product, not just the answer?

From one IBC to a road tanker, delivered to your vessel in Polish ports, with the certificate of analysis for your batch.

  • Urea solution 40% (AUS 40)
  • Caustic soda 50% (NaOH)

Related guides

Call us Request delivery slot