onlinechem.pl marine
Technical guide

How much caustic soda does a closed-loop scrubber use?

Published figures range from 6 to 18 litres per MWh. Here is where that range comes from, how to narrow it for your vessel, and when a tanker beats pallets of IBCs.

Updated: 18 November 2026

Between 6 and 18 litres of 50% caustic soda per MWh, scaling with fuel sulphur at roughly 6 l/MWh for each percentage point. Wärtsilä’s estimate for scrubbing 3.5% sulphur fuel down to a 0.1% equivalent is about 18 l/MWh. As a sanity check, stoichiometry gives 1.25 kg of sodium hydroxide per kilogram of SO₂ removed.

Why nobody gives you one number

If you have already searched this, you have seen figures that look irreconcilable. They are not wrong so much as differently based. Here is what is actually being compared:

FigureBasisSource
1–15 l/h per MWdosing rate, generalscientific review
11 l/MWh ≈ 2.9% S; 1 l/MWh ≈ 0.9% S50% solution, by fuel sulphursame review
~18 l/MWh50% solution, 3.5% S down to 0.1% equivalentWärtsilä, via ABS guidance
6–18 l/MWh, ~6 l/MWh per 1% S50% solutionUmweltbundesamt
1.25 kg NaOH per kg SO₂stoichiometry, 100% NaOHUmweltbundesamt
23 kg/MWh at 2.7% Smass, hybrid systems onlyacademic thesis
58 kg per tonne of fuel10 MW engine, 3.5% HSFOtrade press

Three traps are hiding in that table. Litres of 50% solution and kilograms of sodium hydroxide differ by a factor of two, because half the solution is water. The assumed fuel sulphur ranges from under 1% to 3.5%, which alone moves the answer by an order of magnitude. And several of the widely quoted figures trace back to studies from 2011 and 2012.

How to narrow it for your vessel

The honest method is to work from what you know rather than from someone else’s average. Four inputs decide it:

  1. Engine power under treatment — not the total installed power, only what the scrubber actually handles.
  2. Average load — the difference between 60% and 90% is a third of your consumption.
  3. Hours per day in closed mode — for a hybrid, this is the hours inside waters where open-loop discharge is prohibited.
  4. Fuel sulphur — the single largest multiplier.

Our estimator takes those four and returns a range rather than a point, with the assumptions visible. It also converts to IBCs, which is the unit you actually order in.

A worked example

An 8 MW engine at 70% load, running 8 hours a day in closed mode on fuel at 2.5% sulphur, works out at roughly 470 to 810 litres per day — about 3 to 6 IBCs over a five-day voyage. Whatever the estimate says, your exhaust gas cleaning system documentation is the binding source.

What else the system consumes

Caustic is not the only consumable. A closed-loop circuit needs fresh water topping up to compensate evaporation and the extracted bleed-off — Wärtsilä suggests roughly 0.2 m³/MWh as an estimate. Bleed-off itself runs at 0.1–0.3 m³/MWh for freshwater systems, which Wärtsilä puts at around 250 times less water discharged than a seawater scrubber.

Before you calculate anything: does your system use caustic at all?

Only closed-loop systems and hybrids in closed mode consume sodium hydroxide. Open-loop systems use the natural alkalinity of seawater and consume nothing. Dry systems use calcium hydroxide granulate.

And one more check worth making before ordering: the Alfa Laval PureSOx water cleaning system can run on sodium hydroxide or magnesium hydroxide, and the 2.0 version also allows powdered sodium bicarbonate. Chemically, caustic needs two ions per sulphur capture where magnesium hydroxide needs one. So the first question in a quotation is not "how much" but "which system and which reagent".

Questions we get asked

How much caustic soda does a closed-loop scrubber use per MWh?

Published figures sit between 6 and 18 litres of 50% solution per MWh, scaling with the sulphur content of the fuel at roughly 6 litres per MWh for each percentage point of sulphur. Wärtsilä’s own estimate, cited in ABS guidance, is about 18 l/MWh when scrubbing 3.5% sulphur fuel down to a 0.1% equivalent.

Why do published figures vary so much?

Because they are not measuring the same thing. Some are litres of 50% solution, some are kilograms of sodium hydroxide; the fuel sulphur assumed ranges from under 1% to 3.5%; and the depth of removal differs. Several widely quoted figures also trace back to studies from 2011 and 2012.

Does an open-loop scrubber use caustic soda?

No. An open-loop system uses the natural alkalinity of seawater. Only closed-loop systems, and hybrids running in closed mode, consume sodium hydroxide.

At what point does a road tanker beat pallets of IBCs?

As a rule of thumb, once a single delivery passes roughly six IBCs. Below that, IBCs are easier to lift aboard and to store. Above it, the handling and the number of lifts start to dominate, and a tanker of up to about 24 tonnes becomes the sensible option — partial loads of 8 to 12 tonnes are also possible.

Sources

  • Umweltbundesamt, Scrubber on Ships factsheet (April 2026) — 6–18 l/MWh of 50% solution; about 6 l/MWh per percentage point of sulphur; 1.25 kg NaOH per kg SO₂; bleed-off 0.1–0.3 m³/MWh.
  • Wärtsilä via ABS, Advisory on Exhaust Gas Scrubber Systems — about 18 l/MWh for 3.5% to 0.1% sulphur; caustic dosed automatically to hold process pH; fresh water top-up about 0.2 m³/MWh; freshwater scrubber discharges roughly 250 times less water.
  • Scientific review of marine exhaust gas treatment systems — 1–15 l/h per MW; 11 l/MWh at 2.9% sulphur equivalent, 1 l/MWh at 0.9%.
  • Academic thesis — 23 kg/MWh at 2.7% sulphur, hybrid systems only.
  • Riviera Maritime Media — 58 kg of caustic per tonne of fuel, 10 MW engine on 3.5% HSFO.
  • Alfa Laval PureSOx — operation on NaOH or Mg(OH)₂; PureSOx 2.0 also on sodium bicarbonate.
  • onlinechem.pl product card — road tanker up to about 24 t, partial loads 8–12 t on request.

Need the product, not just the answer?

From one IBC to a road tanker, delivered to your vessel in Polish ports, with the certificate of analysis for your batch.

  • Urea solution 40% (AUS 40)
  • Caustic soda 50% (NaOH)

Related guides

Call us Request delivery slot